(4) – Connecting the EK8X conical encoder with the connection unit in the terminal box
- Unscrew the screws [123] to remove the terminal box cover [132].
- Remove the cover of the connection unit [1522] by pressing the cover on both sides behind the cable bushing.
- Connect the customer's evaluation unit for the encoder to the connection unit [1522] with a shield plate [1970]. Attach the cover of the connection unit [1522].
- Mount the terminal box cover [132] using the screws [123] (4 × M5 SW8).
- Tightening torque 4 Nm