RK8M encoder – Terminal strip or M23 in the terminal box – AIGA, AIGB – MOVIDRIVE®

[1]

DR.. motors with terminal strip in the terminal box for encoder signals without/with TF thermal monitoring.

Encoder: RK8M

Connector on the inverter: D-Sub15.

The signals for thermal monitoring of the motor are transmitted in the encoder cable.

[2]

DR.. motors with terminal strip in the terminal box for encoder signals without/with TF thermal monitoring.

Encoder: RK8M

Connector on the inverter: D-Sub9.

The signals for thermal monitoring of the motor are transmitted in the encoder cable.

[3]

DR.. motors with M23 connector on the terminal box for encoder signals without/with TF thermal monitoring.

Connection type: AIGA/AIGB

Encoder: RK8M

Connector on the inverter: D-Sub15.

The signals for thermal monitoring of the motor are transmitted in the encoder cable.

[4]

DR.. motors with M23 connector on the terminal box for encoder signals without/with TF thermal monitoring.

Connection type: AIGA/AIGB

Encoder: RK8M

Connector on the inverter: D-Sub9.

The signals for thermal monitoring of the motor are transmitted in the encoder cable.