Fault 16 Startup
Subfault: 16.14 Description: PWM frequency noise not possible | ||
|---|---|---|
| Response: Output stage inhibit + line contactor unchanged + module bus response "Standard" | |
Cause | Measure | |
The activation of "PWM noise" (index 8812.145) is not allowed in this device configuration. | For information only. | |
Subfault: 16.30 Description: Faulty EtherCAT® EEPROM configuration state | ||
|---|---|---|
| Response: Output stage inhibit + open line contactor + module bus response "Critical" | |
Cause | Measure | |
Faulty EtherCAT®/SBusPLUS EEPROM configuration status. EEPROM not loaded; binary file not loaded. | Contact SEW‑EURODRIVE Service. | |
Faulty EEPROM loading procedure. | Contact SEW‑EURODRIVE Service. | |
Faulty EEPROM checksum. | Contact SEW‑EURODRIVE Service. | |