Standard path segments with variable size

INFORMATION

The numbering of the process data does not refer to the absolute number in the fieldbus interface but is only the relative number in the standard path segment.

INFORMATION

When initializing the MOVI-C® CONTROLLER (SEW_PRG.Init), the SRL variables used by the process data interface are assigned names that also provide information about the exact process data word and the bit. To view this, open the RobotMonitor after configuring and starting the MOVI-C® CONTROLLER and scroll to the corresponding position in the SRL variable list. This automatic naming can be deactivated in order to use customer-specific names by setting "Name used SRL variables automatically" in the "Fieldbus configuration" section of the "Fieldbus interface" > "Basic settings" configuration menu.

Word

Bit

In

Description

PO 1

0-3

Motion parameter set

Selection of the motion parameter set for this path segment via the 4 bits as NIBBLE.

4

Wait point

TRUE – Stopping at the previous pose is forced

FALSE – Enable for traveling this path segment if the path has not already been terminated by a path end (bit 5).

5

End point

TRUE – End program at this target pose. Only the first path end (across all path segments in the entire telegram) is effective.

 

PO 2

0-15

Blending distance

Blending distance between the last path segment and this path segment (i.e. at the target pose of the last path segment)

PO 3 to 2+p*

0-15

Target pose

Target pose specification for this path segment

* p = pose size, see chapter Poses. Default value: 4.