Fault 18 Software error

Error: 18.3 (1203hex | 4611dec)

Description: Task system – warning

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

Error detected while processing internal task system.

– Acknowledge the warning.

– If the warning occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 18.4 (1204hex | 4612dec)

Description: Task system – error

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

Error detected while processing internal task system.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 18.7 (1207hex | 4615dec)

Description: Fatal software error

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

Fatal software error.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 18.8 (1208hex | 4616dec)

Description: Invalid fault code

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

Invalid fault code requested.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 18.9 (1209hex | 4617dec)

Description: Internal software error

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

The software has reported an unexpected event.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 18.10 (120Ahex | 4618dec)

Description: Watchdog error

 

Response: Remote – critical fault

System state: Fault acknowledgment with CPU reset

Cause

Measure

Watchdog has detected an error. The software is not operating within the intended cycle time.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.