Fault 228 Process variable 1
Fault: 228.0 (E400hex | 58368dec) Description: Process variable 1 – value too high | ||
|---|---|---|
|
| |
Cause | Measure | |
The value of process variable 1 has exceeded the maximum permitted value. | Reduce the torque/load. | |
The value of process variable 1 has exceeded the maximum permitted value. | Observe the operating instructions of the connected sensor. | |
Fault: 228.1 (E401hex | 58369dec) Description: Process variable 1 – value high | ||
|---|---|---|
|
| |
Cause | Measure | |
The value of process variable 1 is close to the maximum permitted value. | Check process variable 1. | |
The value of process variable 1 is close to the maximum permitted value. | Contact SEW-EURODRIVE Service. | |