Fault 212 Vibration velocity

Fault: 212.0 (D400hex | 54272dec)

Description: Effective vibration velocity too high

 

 

Cause

Measure

Effective vibration velocity has exceeded the maximum permitted value.

Have an expert analysis performed by SEW-EURODRIVE.

Effective vibration velocity has exceeded the maximum permitted value.

Reduce the torque/load.

Fault: 212.1 (D401hex | 54273dec)

Description: Effective vibration velocity high

 

 

Cause

Measure

Effective vibration velocity is remarkably high.

Have an expert analysis performed by SEW-EURODRIVE.

Effective vibration velocity is remarkably high.

Contact SEW-EURODRIVE to schedule a service appointment.