Mounting position MX
Mounting position MX is available for all gear units of sizes R..7, F..7, K..7, K..9, S..7 and SPIROPLAN® W..9.
Before startup, make adjustments dependent on the mounting position for gear units in mounting position MX.
In the mounting position MX, the gear units are delivered with the maximum required oil fill quantity and sealed with oil screw plugs. A breather valve is included with each drive. You must adjust the oil fill quantity of the gear unit according to the mounting position in which the gear unit is operated (see chapter Lubricant fill quantities). You must also mount the enclosed breather valve to the position depending on the mounting position, see chapter Mounting position sheets.