Variable mounting position

The variable mounting position is available on request for gear units of the types R..7, F..7, K..7, K..9, S..7 and SPIROPLAN® W..9.

For gear units with variable mounting position, you must perform mounting position-dependent adjustments before startup. Adjustment of the oil fill quantity is not required.

With the variable mounting position, the gear units are delivered with the maximum required oil fill quantity of the mentioned mounting positions and sealed with oil screw plugs. A breather valve is included if necessary.

The enclosed breather valve must be mounted in the proper location depending on the mounting position, see chapter Mounting position sheets.