Fieldbus interface

Parameter designation

Description

Fieldbus configuration

Activate fieldbus connection

Activation or deactivation of the fieldbus connection. The fieldbus connection is deactivated as standard.

Index: 50000.150

IEC name:

Start address

Start address of the fieldbus process data words in the array of the bus system. Counting starts at 1

Index: 50000.151

IEC name:

Basic process data

Number of pieces of process data for the software module without activated "Additional functions"

Index: 50000.159

IEC name:

Process data of functions in use

Additional process data of the activated "Additional functions"

Index: 50000.161

IEC name:

Process data for additional process values of the inverter

Additional process values of the inverter

Index: 50000.104

IEC name:

Optional process data

Additional process data due to the activated "Optional process data"

Index:

IEC name:

Additional process data for user program

Additional process data not assigned by the software module and freely assignable by the user

The assignment of this process data must be programmed in the IEC program.

Index: 50000.160

IEC name:

Process data length

Length of the process data of the software module

Index:

IEC name:

Optional process data

Position controller control word/status word

 

INFORMATION: Only visible if the additional function "Position controller" is activated.

Activation and deactivation of the position controller or the external encoder

Index: 50000.186

IEC name:

Anti-sway control

 

INFORMATION: Only visible if the additional function "Position controller" is activated.

Display the additional optional process data for the "Anti-sway control" function

Index: 50000.174

IEC name:

Status word/control word

 

INFORMATION: Only visible when the optional anti-sway control process data word is activated.

Activation and deactivation of anti-sway control and feedback of whether it is active

Index: 50000.175

IEC name:

Payload mass

 

INFORMATION: Only visible when the optional anti-sway control process data word is activated.

Order-related modification of the payload configuration

Index: 50000.176

IEC name:

Distance between lifting and traveling trolley

 

INFORMATION: Only visible when the optional anti-sway control process data word is activated.

Order-related change of the "Distance between lifting and traveling trolley"

Index: 50000.177

IEC name:

Actual position of the external encoder

 

INFORMATION: Only visible if the additional function "Position controller" is activated.

Actual position of the external encoder without integration of the motor encoder for position controller in combined operation

Index: 50000.187

IEC name:

Decimal places via fieldbus

Definition of the number of decimal places for position, speed, acceleration, and jerk via fieldbus

INFORMATION: Negative values can also be set for the jerk. These then correspond to the pre-decimal places of the jerk. For example, if -1 is set for the number of decimal places and 1000 is set for the jerk, a jerk of 10 000 results. Even jerk values greater than 16 bits can therefore be traveled.

Index: 50000.155 (position), 50000.156 (speed), 50000.157 (acceleration), 50000.158 (jerk)

PROFINET diagnostic alarms

Activate diagnostic alarms

 

INFORMATION: A current device description file must be available for the texts to be displayed correctly.

Sending of faults and warnings as PROFINET diagnostic alarm for the reading of the texts in plain text

Index: 50000.164

IEC name:

Slot number

Position of the software module on the fieldbus

Slot number 1 corresponds to the 1st freely available slot. For more information, refer to the "Controllers of the MOVI-C® Modular Automation System – Startup with PROFINET/PROFIsafe" manual

Index:

IEC name:

Fieldbus interface

MOVIKIT® default assignment for process data input PI 4

Actual torque
[0.1% nominal motor torque]

Index: 50040.12

IEC name: