Parameter settings

The following parameters have to be set in MOVITRAC® B other than the factory setting. When you use a FBG11B for setting the parameters, set the values indicated in parenthesis:

  • P100 Setpoint source: RS485 (2)
  • P101 Control signal source: RS485 (1)
  • P871 Setpoint description PO2: Set PO2 to "Speed %", then P876 PO data enable to "Yes".

The speed is now displayed: –100% to +100% correspond to –nmax to +nmax.