Limit switch

Parameter designation

Description

Software limit switch

Monitoring
SW limit switch negative

  • On
  • Activate monitoring of software limit switch negative
  • Off
  • Deactivate monitoring of software limit switch negative

Index: 8572.3

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringNegative

SW limit switch negative

Position of the software limit switch negative

(In user units)

Index: 8572.4

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitNegative

Monitoring
SW limit switch positive

  • On
  • Activate monitoring of software limit switch positive
  • Off
  • Deactivate monitoring of software limit switch positive

Index: 8572.5

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.xActivateMonitoringPositive

SW limit switch positive

Position of the software limit switch positive

(In user units)

Index: 8572.6

IEC name: LimitSwitchEvaluation.SoftwareLimitSwitch.In.lrLimitPositive

Fault response

Response to SW limit switch reached

  • No response
  • Warning
  • Emergency stop + output stage inhibit
  • Emergency stop + output stage inhibit with self-reset

Index: 8572.2

IEC name: Parameter.LimitSwitchData1.SwLsHitResp

Response to HW limit switch reached

  • No response
  • Emergency stop + output stage inhibit
  • Emergency stop + output stage inhibit with self-reset

Index: 8572.1

IEC name: Parameter.LimitSwitchData1.HwLsHitResp