Error 11 Temperature monitoring

Error: 11.1 (0B01hex | 2817dec)

Description: Heat sink overtemperature

 

 

Cause

Measure

The capacity utilization is too high. Maximum permitted heat sink temperature exceeded.

– Reduce the load.

– Reduce the PWM frequency.

– Reduce the ambient temperature.

Air circulation disrupted. Maximum permitted heat sink temperature exceeded.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Maximum permitted heat sink temperature exceeded.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Maximum permitted heat sink temperature exceeded.

Contact SEW-EURODRIVE Service.

Error: 11.2 (0B02hex | 2818dec)

Description: Heat sink utilization – prewarning

 

 

Cause

Measure

High thermal load on heat sink of device. Prewarning threshold reached.

– Reduce the load.

– Reduce the PWM frequency.

– Reduce the ambient temperature.

Air circulation disrupted. Prewarning threshold reached.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

Error: 11.3 (0B03hex | 2819dec)

Description: Device utilization

 

 

Cause

Measure

The mean output current is too high. The device utilization has reached or exceeded the switch-off threshold.

– Reduce the load.

– Check motor/inverter combination.

The PWM frequency is too high. The device utilization has reached or exceeded the switch-off threshold.

Reduce the PWM frequency.

The ambient temperature is too high. The device utilization has reached or exceeded the switch-off threshold.

Reduce the ambient temperature.

Air circulation disrupted. The device utilization has reached or exceeded the switch-off threshold.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. The device utilization has reached or exceeded the switch-off threshold.

Contact SEW-EURODRIVE Service.

Error: 11.5 (0B05hex | 2821dec)

Description: Electromechanical capacity utilization

 

 

Cause

Measure

Electromechanical components of the device overloaded by excessive continuous current.

Reduce the load.

Error: 11.6 (0B06hex | 2822dec)

Description: Electromechanical capacity utilization – prewarning

 

 

Cause

Measure

High load on electromechanical components of the device due to high continuous current. Prewarning threshold reached.

Reduce the load.

Error: 11.7 (0B07hex | 2823dec)

Description: Wire break at temperature sensor of heat sink

 

 

Cause

Measure

Wire break detected at temperature sensor of heat sink.

Contact SEW-EURODRIVE Service.

Error: 11.8 (0B08hex | 2824dec)

Description: Short circuit at temperature sensor of heat sink

 

 

Cause

Measure

Short circuit detected at temperature sensor of heat sink.

Contact SEW-EURODRIVE Service.

Error: 11.9 (0B09hex | 2825dec)

Description: Overtemperature of signal electronics

 

 

Cause

Measure

Maximum permitted temperature of signal electronics exceeded.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.10 (0B0Ahex | 2826dec)

Description: Wire break at temperature sensor of signal electronics

 

 

Cause

Measure

Wire break detected at temperature sensor of signal electronics.

Contact SEW-EURODRIVE Service.

Error: 11.11 (0B0Bhex | 2827dec)

Description: Short circuit at temperature sensor of signal electronics

 

 

Cause

Measure

Short circuit at temperature sensor of signal electronics.

Contact SEW-EURODRIVE Service.

Error: 11.12 (0B0Chex | 2828dec)

Description: Temperature sensor of heat sink faulty

 

 

Cause

Measure

Wire break detected at temperature sensor of heat sink.

Contact SEW-EURODRIVE Service.

Short circuit detected at temperature sensor of heat sink.

Contact SEW-EURODRIVE Service.

Error: 11.13 (0B0Dhex | 2829dec)

Description: Temperature sensor of signal electronics faulty

 

 

Cause

Measure

Wire break detected at temperature sensor of signal electronics.

Contact SEW-EURODRIVE Service.

Short circuit at temperature sensor of signal electronics.

Contact SEW-EURODRIVE Service.

Error: 11.14 (0B0Ehex | 2830dec)

Description: External temperature sensor faulty

 

 

Cause

Measure

Wire break detected at external temperature sensor.

Check the wiring of the external temperature sensor.

Short circuit at external temperature sensor.

Check the wiring of the external temperature sensor.

Error: 11.15 (0B0Fhex | 2831dec)

Description: Overtemperature of precharging unit

 

 

Cause

Measure

The maximum permitted temperature of the precharging unit has been exceeded.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.16 (0B10hex | 2832dec)

Description: Overtemperature of output stage

 

 

Cause

Measure

The maximum permitted output stage temperature has been exceeded. The capacity utilization is possibly too high.

– Reduce the r.m.s. value of the current.

– Ensure sufficient cooling.

– Reduce the ambient temperature.

Error: 11.17 (0B11hex | 2833dec)

Description: Output stage utilization – prewarning

 

 

Cause

Measure

High thermal load on the output stage of the device and prewarning threshold reached.

– Reduce the r.m.s. value of the output current.

– Ensure sufficient cooling.

– Reduce the ambient temperature.

Error: 11.18 (0B12hex | 2834dec)

Description: Overtemperature of transformer

 

 

Cause

Measure

The capacity utilization is too high. The maximum permitted transformer temperature has been exceeded.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.19 (0B13hex | 2835dec)

Description: Temperature sensor of transformer faulty

 

 

Cause

Measure

Wire break detected at temperature sensor of transformer.

Contact SEW-EURODRIVE Service.

Short circuit at temperature sensor of transformer.

Contact SEW-EURODRIVE Service.

Error: 11.20 (0B14hex | 2836dec)

Description: Transformer utilization – prewarning

 

 

Cause

Measure

Air circulation disrupted. Prewarning threshold reached.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

High thermal load on heat sink of device. Prewarning threshold reached.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.21 (0B15hex | 2837dec)

Description: Overtemperature

 

 

Cause

Measure

The capacity utilization is too high. The maximum permitted temperature has been exceeded.

– Reduce the load.

– Reduce the ambient temperature.

Air circulation disrupted.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective.

Contact SEW-EURODRIVE Service.

Temperature sensor defective.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

High thermal load on heat sink of device.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.22 (0B16hex | 2838dec)

Description: Overtemperature – prewarning

 

 

Cause

Measure

Air circulation disrupted. Prewarning threshold reached.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

High thermal load on heat sink of device. Prewarning threshold reached.

– Reduce the load.

– Reduce the ambient temperature.

Error: 11.23 (0B17hex | 2839dec)

Description: Overtemperature

 

 

Cause

Measure

The functionally safe component has determined that the motor utilization is too high.

Reduce the load.

Error: 11.24 (0B18hex | 2840dec)

Description: Overtemperature of the rectifier

 

 

Cause

Measure

The maximum permitted rectifier temperature has been exceeded.

– Ensure sufficient cooling.

– Reduce the ambient temperature.

Air circulation disrupted.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective.

Contact SEW-EURODRIVE Service.

Temperature sensor defective.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

The heat sink of the rectifier is subject to a high thermal load.

Reduce the ambient temperature.

Error: 11.25 (0B19hex | 2841dec)

Description: Rectifier utilization – prewarning

 

 

Cause

Measure

Air circulation disrupted. Prewarning threshold reached.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

The heat sink of the rectifier is subject to a high thermal load. The prewarning threshold has been reached

Reduce the ambient temperature.

Error: 11.26 (0B1Ahex | 2842dec)

Description: Brake chopper overtemperature

 

 

Cause

Measure

The maximum permitted temperature of the brake chopper has been exceeded.

– Reduce the regenerative energy of the system.

– Ensure sufficient cooling.

– Reduce the ambient temperature.

Air circulation disrupted.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective.

Contact SEW-EURODRIVE Service.

Temperature sensor defective.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

The heat sink of the brake chopper is subject to a high thermal load.

Reduce the ambient temperature.

Error: 11.27 (0B1Bhex | 2843dec)

Description: Brake chopper capacity utilization – prewarning

 

 

Cause

Measure

Air circulation disrupted. Prewarning threshold reached.

– Check air circulation.

– Ensure sufficient cooling.

The fan (if available) is defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Temperature sensor defective. Prewarning threshold reached.

Contact SEW-EURODRIVE Service.

Unfavorable air convection.

Check the air convection.

The heat sink of the brake chopper is subject to a high thermal load. Prewarning threshold reached.

Reduce the ambient temperature.

Error: 11.28 (0B1Chex | 2844dec)

Description: Wire break at temperature sensor of rectifier

 

 

Cause

Measure

A wire break was detected at the temperature sensor of the rectifier.

Contact SEW-EURODRIVE Service.

Error: 11.29 (0B1Dhex | 2845dec)

Description: Short circuit at temperature sensor of rectifier

 

 

Cause

Measure

Short circuit at the temperature sensor of the rectifier.

Contact SEW-EURODRIVE Service.

Error: 11.30 (0B1Ehex | 2846dec)

Description: Wire break at temperature sensor of brake chopper

 

 

Cause

Measure

A wire break was detected at the temperature sensor of the brake chopper.

Contact SEW-EURODRIVE Service.

Error: 11.31 (0B1Fhex | 2847dec)

Description: Short circuit at temperature sensor of brake chopper

 

 

Cause

Measure

Short circuit at the temperature sensor of the brake chopper.

Contact SEW-EURODRIVE Service.