Configuration (Config)
Structure with input variables to control the function.
|
Variable name |
Description |
|---|---|
|
eApplicationType
INFORMATION: The availability of the individual application types depends on the version of the software module used. |
Data type – E_APPLICATIONTYPE |
|
Application type of anti-sway control:
| |
|
lrUserUnitToMeter |
Data type – LREAL – Floating-point number |
|
Position relationship between the user unit from the drive train and one meter in [m/user units] If the value is set to "0", the user unit corresponds to the unit [m]. If the value is not "0", the formula user unit*lrUserUnitToMeter = meter applies. The computing time is longer in this case. | |
|
lrUserUnitHoistToMeter |
Data type – LREAL – Floating-point number |
|
Position relationship on the lifting axis between the user unit from the drive train and one meter in [m/user units] If the value is set to "0", the user unit corresponds to the unit [m]. If the value is not "0", the formula user unit*lrUserUnitToMeter = meter applies. The computing time is longer in this case. | |
lrOffsetSwayHeight | Data type - LREAL - Floating-point number |
Difference between the physical height and the actual position of the lifting axis. |