0x8480-12 – Lag error limit error
Index-Sub | Type | RW | Default | Range of values | Unit | Description |
|---|---|---|---|---|---|---|
0x8480-12 | S32 | R/W** | 1000 | -8388608 – 8388607 | (user) | Lag error limit error |
This object defines a limit for the position deviation (lag error). If the limit is reached, this is reported as an error and the function module switches to the error status. You can deactivate lag error monitoring by entering 0.