Fault 25 Parameter memory monitoring
Fault: 25.55 (1937hex | 6455dec) Description: Incompatible safety card parameter set on replaceable memory module | ||
---|---|---|
| Response: FS – warning | |
Cause | Measure | |
Parameter set on replaceable memory module created by incompatible safety card version. | Set the safety card parameters again and validate. |
Fault: 25.56 (1938hex | 6456dec) Description: Corrupt safety card parameter set on replaceable memory module | ||
---|---|---|
| Response: FS – warning | |
Cause | Measure | |
Corrupt safety card parameter set on replaceable memory module. | Set the safety card parameters again and validate. |
Fault: 25.57 (1939hex | 6457dec) Description: Internal communication fault while accessing replaceable memory module | ||
---|---|---|
| Response: FS – warning | |
Cause | Measure | |
Internal communication fault while accessing replaceable memory module. | – Switch the device off and on again. – If the fault occurs repeatedly, replace the safety card and send it together with the fault number to SEW‑EURODRIVE. For further support, contact SEW‑EURODRIVE Service. |
Fault: 25.58 (193Ahex | 6458dec) Description: Fault applying parameter set of safety card from replaceable memory module | ||
---|---|---|
| Response: FS – warning | |
Cause | Measure | |
Failure to apply the parameter set of the safety card from the replaceable memory module can have the following reasons: – The Assist CS.. tool is open. – Another parameterization process is running. | – Switch the device off and on again. – If the fault occurs repeatedly, replace the safety card and send it together with the fault number to SEW‑EURODRIVE. For further support, contact SEW‑EURODRIVE Service. |
Fault: 25.59 (193Bhex | 6459dec) Description: Communication error with the basic unit | ||
---|---|---|
| Response: FS – warning | |
Cause | Measure | |
A fault prevented the changed configuration from being saved to the replaceable memory module. | Switch the device off and on again. |
Fault: 25.100 (1964hex | 6500dec) Description: Device replacement detected | ||
---|---|---|
| Response: FS – message | |
Cause | Measure | |
Current parameter set of safety card differs from parameter set stored on replaceable memory module. | No action required. The parameter set of the replaceable memory module is applied to the safety card. |
Fault: 25.101 (1965hex | 6501dec) Description: Update of data of removable memory module from safety option | ||
---|---|---|
| Response: FS – message | |
Cause | Measure | |
The data on the replaceable memory module has been saved by an earlier version of the safety option. | For information only. |