Fault 60 Safe digital input
Fault: 60.19 (3C13hex | 15379dec) Description: F-DI level change "cam slip adjustment" at wrong position | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
An F-DI edge was detected at an incorrect position during slip adjustment. This can be due to the following reasons: – Cable breakage – Line fault – Incorrect parameterization of the slip adjustment | – Check the cables. – Check the parameterization of the slip adjustment. |
Fault: 60.20 (3C14hex | 15380dec) Description: F-DI Internal fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Fault detected on safety card during internal test of safe digital inputs F-DI. | – Acknowledge the fault. – If the fault occurs repeatedly, replace the safety card and send it together with the fault number to SEW‑EURODRIVE. For further support, contact SEW‑EURODRIVE Service. |
Fault: 60.21 (3C15hex | 15381dec) Description: F-DI Short circuit | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Short circuit detected in external wiring of safe digital inputs F-DI. | – Check external wiring. – Acknowledge the fault. |
Fault: 60.22 (3C16hex | 15382dec) Description: F-DI 00/01 Discrepancy fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Discrepancy fault F‑DI 00/01: – The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 00/01 has been exceeded, or a fault has been detected in a subchannel. – Switch test condition not fulfilled. | – Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 00/01. – Check the parameterization of the safety card and increase the discrepancy time if necessary. – If the switch test function at F‑DI 00/01 is active, make sure that the switch test condition is fulfilled before acknowledging the fault. – Acknowledge the fault. |
Fault: 60.24 (3C18hex | 15384dec) Description: F-DI 02/03 Discrepancy fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Discrepancy fault F‑DI 02/03: – The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 02/03 has been exceeded, or a fault has been detected in a subchannel. – Switch test condition not fulfilled. | – Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 02/03. – Check the parameterization of the safety card and increase the discrepancy time if necessary. – If the switch test function at F‑DI 02/03 is active, make sure that the switch test condition is fulfilled before acknowledging the fault. – Acknowledge the fault. |
Fault: 60.26 (3C1Ahex | 15386dec) Description: F-DI 04/05 Discrepancy fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Discrepancy fault F‑DI 04/05: – The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 04/05 has been exceeded, or a fault has been detected in a subchannel. – Switch test condition not fulfilled. | – Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 04/05. – Check the parameterization of the safety card and increase the discrepancy time if necessary. – If the switch test function at F‑DI 04/05 is active, make sure that the switch test condition is fulfilled before acknowledging the fault. – Acknowledge the fault. |
Fault: 60.28 (3C1Chex | 15388dec) Description: F-DI 06/07 Discrepancy fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Discrepancy fault F‑DI 06/07: – The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 06/07 has been exceeded, or a fault has been detected in a subchannel. – Switch test condition not fulfilled. | – Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 06/07. – Check the parameterization of the safety card and increase the discrepancy time if necessary. – If the switch test function at F‑DI 06/07 is active, make sure that the switch test condition is fulfilled before acknowledging the fault. – Acknowledge the fault. |
Fault: 60.32 (3C20hex | 15392dec) Description: F-DI 00 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 00 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 00 for crossfault. – Acknowledge the fault. |
Fault: 60.33 (3C21hex | 15393dec) Description: F-DI 01 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 01 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 01 for crossfault. – Acknowledge the fault. |
Fault: 60.34 (3C22hex | 15394dec) Description: F-DI 02 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 02 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 02 for crossfault. – Acknowledge the fault. |
Fault: 60.35 (3C23hex | 15395dec) Description: F-DI 03 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 03 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 03 for crossfault. – Acknowledge the fault. |
Fault: 60.36 (3C24hex | 15396dec) Description: F-DI 04 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 04 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 04 for crossfault. – Acknowledge the fault. |
Fault: 60.37 (3C25hex | 15397dec) Description: F-DI 05 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 05 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 05 for crossfault. – Acknowledge the fault. |
Fault: 60.38 (3C26hex | 15398dec) Description: F-DI 06 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 06 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 06 for crossfault. – Acknowledge the fault. |
Fault: 60.39 (3C27hex | 15399dec) Description: F-DI 07 Crossfault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Crossfault detected at safe digital input F-DI 07 or plausibility test failed. | – Check the external wiring/connection of safe digital input F‑DI 07 for crossfault. – Acknowledge the fault. |
Fault: 60.40 (3C28hex | 15400dec) Description: F-DI 00 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 00. No stable input signal at F‑DI 00 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 00. – Increase the parameter "Input filter time" at F‑DI 00. – Acknowledge the fault. |
Fault: 60.41 (3C29hex | 15401dec) Description: F-DI 01 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 01. No stable input signal at F‑DI 01 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 01. – Increase the parameter "Input filter time" at F‑DI 01. – Acknowledge the fault. |
Fault: 60.42 (3C2Ahex | 15402dec) Description: F-DI 02 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 02. No stable input signal at F‑DI 02 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 02. – Increase the parameter "Input filter time" at F‑DI 02. – Acknowledge the fault. |
Fault: 60.43 (3C2Bhex | 15403dec) Description: F-DI 03 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 03. No stable input signal at F‑DI 03 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 03. – Increase the parameter "Input filter time" at F‑DI 03. – Acknowledge the fault. |
Fault: 60.44 (3C2Chex | 15404dec) Description: F-DI 04 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 04. No stable input signal at F‑DI 04 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 04. – Increase the parameter "Input filter time" at F‑DI 04. – Acknowledge the fault. |
Fault: 60.45 (3C2Dhex | 15405dec) Description: F-DI 05 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 05. No stable input signal at F‑DI 05 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 05. – Increase the parameter "Input filter time" at F‑DI 05. – Acknowledge the fault. |
Fault: 60.46 (3C2Ehex | 15406dec) Description: F-DI 06 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 06. No stable input signal at F‑DI 06 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 06. – Increase the parameter "Input filter time" at F‑DI 06. – Acknowledge the fault. |
Fault: 60.47 (3C2Fhex | 15407dec) Description: F-DI 07 Connection fault | ||
---|---|---|
| Response: FS – input fault | |
Cause | Measure | |
Maximum response time exceeded at safe digital input F‑DI 07. No stable input signal at F‑DI 07 within the parameterized input filter time. | – Check the switch/sensor connected to safe digital input F‑DI 07. – Increase the parameter "Input filter time" at F‑DI 07. – Acknowledge the fault. |