Fault 60 Safe digital input

Fault: 60.19 (3C13hex | 15379dec)

Description: F-DI level change "cam slip adjustment" at wrong position

 

Response: FS – input fault

Cause

Measure

An F-DI edge was detected at an incorrect position during slip adjustment. This can be due to the following reasons:

– Cable breakage

– Line fault

– Incorrect parameterization of the slip adjustment

– Check the cables.

– Check the parameterization of the slip adjustment.

Fault: 60.20 (3C14hex | 15380dec)

Description: F-DI Internal fault

 

Response: FS – input fault

Cause

Measure

Fault detected on safety card during internal test of safe digital inputs F-DI.

– Acknowledge the fault.

– If the fault occurs repeatedly, replace the safety card and send it together with the fault number to SEW‑EURODRIVE. For further support, contact SEW‑EURODRIVE Service.

Fault: 60.21 (3C15hex | 15381dec)

Description: F-DI Short circuit

 

Response: FS – input fault

Cause

Measure

Short circuit detected in external wiring of safe digital inputs F-DI.

– Check external wiring.

– Acknowledge the fault.

Fault: 60.22 (3C16hex | 15382dec)

Description: F-DI 00/01 Discrepancy fault

 

Response: FS – input fault

Cause

Measure

Discrepancy fault F‑DI 00/01:

– The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 00/01 has been exceeded, or a fault has been detected in a subchannel.

– Switch test condition not fulfilled.

– Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 00/01.

– Check the parameterization of the safety card and increase the discrepancy time if necessary.

– If the switch test function at F‑DI 00/01 is active, make sure that the switch test condition is fulfilled before acknowledging the fault.

– Acknowledge the fault.

Fault: 60.24 (3C18hex | 15384dec)

Description: F-DI 02/03 Discrepancy fault

 

Response: FS – input fault

Cause

Measure

Discrepancy fault F‑DI 02/03:

– The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 02/03 has been exceeded, or a fault has been detected in a subchannel.

– Switch test condition not fulfilled.

– Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 02/03.

– Check the parameterization of the safety card and increase the discrepancy time if necessary.

– If the switch test function at F‑DI 02/03 is active, make sure that the switch test condition is fulfilled before acknowledging the fault.

– Acknowledge the fault.

Fault: 60.26 (3C1Ahex | 15386dec)

Description: F-DI 04/05 Discrepancy fault

 

Response: FS – input fault

Cause

Measure

Discrepancy fault F‑DI 04/05:

– The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 04/05 has been exceeded, or a fault has been detected in a subchannel.

– Switch test condition not fulfilled.

– Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 04/05.

– Check the parameterization of the safety card and increase the discrepancy time if necessary.

– If the switch test function at F‑DI 04/05 is active, make sure that the switch test condition is fulfilled before acknowledging the fault.

– Acknowledge the fault.

Fault: 60.28 (3C1Chex | 15388dec)

Description: F-DI 06/07 Discrepancy fault

 

Response: FS – input fault

Cause

Measure

Discrepancy fault F‑DI 06/07:

– The parameterized discrepancy time in 2-channel evaluation of the safe digital inputs F‑DI 06/07 has been exceeded, or a fault has been detected in a subchannel.

– Switch test condition not fulfilled.

– Check the 2-channel switch/sensor connected to the safe digital input pair F‑DI 06/07.

– Check the parameterization of the safety card and increase the discrepancy time if necessary.

– If the switch test function at F‑DI 06/07 is active, make sure that the switch test condition is fulfilled before acknowledging the fault.

– Acknowledge the fault.

Fault: 60.32 (3C20hex | 15392dec)

Description: F-DI 00 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 00 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 00 for crossfault.

– Acknowledge the fault.

Fault: 60.33 (3C21hex | 15393dec)

Description: F-DI 01 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 01 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 01 for crossfault.

– Acknowledge the fault.

Fault: 60.34 (3C22hex | 15394dec)

Description: F-DI 02 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 02 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 02 for crossfault.

– Acknowledge the fault.

Fault: 60.35 (3C23hex | 15395dec)

Description: F-DI 03 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 03 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 03 for crossfault.

– Acknowledge the fault.

Fault: 60.36 (3C24hex | 15396dec)

Description: F-DI 04 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 04 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 04 for crossfault.

– Acknowledge the fault.

Fault: 60.37 (3C25hex | 15397dec)

Description: F-DI 05 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 05 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 05 for crossfault.

– Acknowledge the fault.

Fault: 60.38 (3C26hex | 15398dec)

Description: F-DI 06 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 06 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 06 for crossfault.

– Acknowledge the fault.

Fault: 60.39 (3C27hex | 15399dec)

Description: F-DI 07 Crossfault

 

Response: FS – input fault

Cause

Measure

Crossfault detected at safe digital input F-DI 07 or plausibility test failed.

– Check the external wiring/connection of safe digital input F‑DI 07 for crossfault.

– Acknowledge the fault.

Fault: 60.40 (3C28hex | 15400dec)

Description: F-DI 00 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 00. No stable input signal at F‑DI 00 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 00.

– Increase the parameter "Input filter time" at F‑DI 00.

– Acknowledge the fault.

Fault: 60.41 (3C29hex | 15401dec)

Description: F-DI 01 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 01. No stable input signal at F‑DI 01 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 01.

– Increase the parameter "Input filter time" at F‑DI 01.

– Acknowledge the fault.

Fault: 60.42 (3C2Ahex | 15402dec)

Description: F-DI 02 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 02. No stable input signal at F‑DI 02 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 02.

– Increase the parameter "Input filter time" at F‑DI 02.

– Acknowledge the fault.

Fault: 60.43 (3C2Bhex | 15403dec)

Description: F-DI 03 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 03. No stable input signal at F‑DI 03 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 03.

– Increase the parameter "Input filter time" at F‑DI 03.

– Acknowledge the fault.

Fault: 60.44 (3C2Chex | 15404dec)

Description: F-DI 04 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 04. No stable input signal at F‑DI 04 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 04.

– Increase the parameter "Input filter time" at F‑DI 04.

– Acknowledge the fault.

Fault: 60.45 (3C2Dhex | 15405dec)

Description: F-DI 05 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 05. No stable input signal at F‑DI 05 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 05.

– Increase the parameter "Input filter time" at F‑DI 05.

– Acknowledge the fault.

Fault: 60.46 (3C2Ehex | 15406dec)

Description: F-DI 06 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 06. No stable input signal at F‑DI 06 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 06.

– Increase the parameter "Input filter time" at F‑DI 06.

– Acknowledge the fault.

Fault: 60.47 (3C2Fhex | 15407dec)

Description: F-DI 07 Connection fault

 

Response: FS – input fault

Cause

Measure

Maximum response time exceeded at safe digital input F‑DI 07. No stable input signal at F‑DI 07 within the parameterized input filter time.

– Check the switch/sensor connected to safe digital input F‑DI 07.

– Increase the parameter "Input filter time" at F‑DI 07.

– Acknowledge the fault.