Work steps with electronics cover size 1
NOTICE
Loss of the guaranteed degree of protection.
Damage to property.
- When the cover is removed from the connection box, the cover and the wiring space must be protected from humidity, dust or foreign particles.
Replace the gasket of MOVIMOT® flexible as follows:
- Perform the steps according to chapter Preliminary work regarding inspection and maintenance.
- Loosen the screws of the electronics cover and remove it.
- Loosen the used seal by levering it off the retaining cams.
- Disassembly is easier if you adhere to the sequence shown in the following figure.
- Remove the old gasket completely from the connection box.
- Carefully clean the sealing surfaces of the connection box and the electronics cover.
- Place the new gasket on the connection box and fix it with the retaining cams. Installation is facilitated if you follow the illustrated order.
- Check the installation and startup of the device using the applicable operating instructions.
- Place the electronics cover back onto the connection box and secure it.
- Proceed as follows when mounting the electronics cover: Insert/screw in the screws and tighten them in diametrically opposite sequence step by step with a tightening torque of 6.0 Nm.