Replacing the memory module
Replace the memory module as follows:
- Consider the safety notes in chapter Creating a safe working environment.
- Make sure the device is de-energized. The 400 V line voltage and the 24 V backup voltage must be disconnected.
- Loosen the screws and remove the electronics cover from the connection box.
- Remove the memory module from the old electronics cover.
- Compare the part number and the status of the memory module.
INFORMATION
The new memory module must have the same part number and the same (or a higher) status as the old memory module.
- Set the DIP switches on the new memory module in the same way as the control elements of the previous memory module.
- Insert the new memory module into the electronics cover.
- Place the electronics cover onto the connection box and screw it in place.
- Supply the device with voltage.
- Check the startup of the device.
- If required, perform startup again or load the saved startup to the device.
- For devices with safety card, check the startup of the safety card. For further information, refer to the product manual > chapter "Project planning for functional safety" > "Safety conditions" > "Startup requirements".
- Check the functionality of the new electronics cover.
If the device was ordered with the option /P "Parameters ex works", the customer-specific parameter set is saved on the supplied memory module upon delivery.
When ordering a new memory module using the part number, no data set is stored on the memory module.
- Start up the device manually.
- As an alternative, save the data set of a previously created data backup to the memory module. Start up the device with the saved data set.