Configuring the digital inputs/outputs

Easy mode

In Easy mode, the following configuration of the digital inputs is active:

Digital inputs

Function

(Configuration of the digital inputs)

Setting

(CW/CCW/setpoint changeover)

  • DI01

Fixed setpoints, positive rotation direction

  • DI02

Fixed setpoints, negative rotation direction

  • DI03

Potentiometer f2

  • DI04

Fault reset

Digital outputs

Function

Setting

DOR (relay output)

Ready

Easy mode is only available up to firmware version < 11.

Expert mode

In Expert mode, you can assign other functions to the digital inputs and to the relay output, either individually or using predefined configurations of the digital inputs.