Requirements for the supply

The product can be supplied with power in various ways:

  • Power supply directly via cable or sliding contacts
  • MOVI‑DPS® energy storage units and accumulators (short-term or long-term supply)
  • MOVITRANS® centralized contactless energy transfer system

Observe the following:

  • Select the DC voltage range of the supply to match the technical data of the product.
  • Configure the cables and fuses according to the intended application. When doing so, observe the applicable safety regulations and standards.
  • For regenerative applications, use a suitable overcurrent protection device such as a brake chopper or a sufficiently large DC link buffer.
  • The charge/discharge management function of the MOVI-DPS® energy storage units and/or the accumulators
  • The line protection of the product and/or the capacitors or accumulators
  • The maximum current limit in the event of a short circuit
  • The equipotential bonding of all automation components must be ensured.
  • The regenerative energy during deceleration must be calculated correctly.