Error 122 – Axis group

Error: 122.0 (7A00hex | 31232dec)

Description: Object interface not linked

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

The library version does not match the code-generated IEC project.

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Error: 122.1 (7A01hex | 31233dec)

Description: Access to subordinate axis group member blocked

 

Response: No response

Cause

Measure

The access to a subordinat axis group member has been requested by a prioritized location.

Return access to the subordinate axis group member to its interfaces (e.g. UI, HMI, PD).

Error: 122.2 (7A02hex | 31234dec)

Description: Access to subordinate axis group member cannot be returned

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.3 (7A03hex | 31235dec)

Description: Interface "itfQueryInterfaceSEW" is 0

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

The library version does not match the code-generated IEC project.

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Error: 122.4 (7A04hex | 31236dec)

Description: No axis group members linked to axis group

 

Response: No response

Cause

Measure

No axis group members have been linked to the axis group.

Link the axis group members beneath the software node in MOVISUITE®.

Error: 122.5 (7A05hex | 31237dec)

Description: Index variable of linked axis group members outside valid value range (1-16)

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.6 (7A06hex | 31238dec)

Description: Too many subordinate axis group members

 

Response: No response

Cause

Measure

There are too many axis group members.

Link up to 16 axis group members beneath the software node in MOVISUITE®.

Error: 122.32 (7A20hex | 31264dec)

Description: Interface unoccupied

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

The library version does not match the code-generated IEC project.

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Error: 122.33 (7A21hex | 31265dec)

Description: Index variable of linked axes outside valid range of values

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.34 (7A22hex | 31266dec)

Description: Axis group member signals too many Touchprobe events (overflow)

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.35 (7A23hex | 31267dec)

Description: Erroneous feedback of Touchprobe of axis group member

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

At least one of the subordinate axis group members is not connected to the Touchprobe sensor.

– Connect a Touchprobe sensor to all axis group members of the robot.

– Check the wiring.

Error: 122.36 (7A24hex | 31268dec)

Description: Axis group member reached maximum or minimum position value (overflow)

 

Response: No response

Cause

Measure

An axis group member has reached its maximum/minimum value for the set position resolution.

Increase the number of decimal places for the position resolution by the maximum/minimum value in MOVISUITE®.

Error: 122.37 (7A25hex | 31269dec)

Description: Unable to determine cycle time

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.38 (7A26hex | 31270dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling "Not connected".

Check the status of the subordinate axis group member in its interface.

Error: 122.39 (7A27hex | 31271dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling "Not ready" during the interpolation of the profile generators.

Check the status of the subordinate axis group member in its interface.

Error: 122.40 (7A28hex | 31272dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling "Not referenced".

Check the status of the subordinate axis group member in its interface.

Error: 122.41 (7A29hex | 31273dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling "Not setpoint active" during the interpolation of the profile generators.

Check the status of the subordinate axis group member in its interface.

Error: 122.42 (7A2Ahex | 31274dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling the wrong inverter operating mode.

Check the status of the subordinate axis group member in its interface.

Error: 122.43 (7A2Bhex | 31275dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is not in interpolation.

Check the status of the subordinate axis group member in its interface.

Error: 122.44 (7A2Chex | 31276dec)

Description: Erroneous cycle limit setting

 

Response: No response

Cause

Measure

At least one subordinate axis group member has an invalid cycle limit in interaction with robotics.

Define the value 0.0 for the modulo minimum and modulo maximum of the cycle limitation.

Error: 122.45 (7A2Dhex | 31277dec)

Description: Unexpected status of subordinate axis group member

 

Response: No response

Cause

Measure

At least one subordinate axis group member of the robot is signaling "Not ready" during the positioning of the profile generators.

Check the status of the subordinate axis group member in its interface.

Error: 122.46 (7A2Ehex | 31278dec)

Description: At least one subordinate axis group member has not signaled a Touchprobe event

 

Response: No response

Cause

Measure

At least one of the subordinate axis group members is not connected to the Touchprobe sensor.

– Connect a Touchprobe sensor to all axis group members of the robot.

– Check the wiring.

Error: 122.64 (7A40hex | 31296dec)

Description: Positive hardware limit switch configured in input assignment of inverter and in MultiAxis controller

 

 

Response: No response

Cause

Measure

The positive hardware limit switch has been configured in the input assignment of the inverter and in the MultiAxis controller. The error response of the inverter overshadows the correct functionality of the MultiAxis controller.

– Remove the hardware limit switch as a digital input in MOVISUITE® under [Inputs/Outputs].

– Deactivate the hardware limit switch for the MultiAxis controller in MOVISUITE® under [Monitoring functions].

Error: 122.65 (7A41hex | 31297dec)

Description: Negative hardware limit switch configured in input assignment of inverter and in MultiAxis controller

 

 

Response: No response

Cause

Measure

The negative hardware limit switch has been configured in the input assignment of the inverter and in the MultiAxis controller. The error response of the inverter overshadows the correct functionality of the MultiAxis controller.

– Remove the hardware limit switch as a digital input in MOVISUITE® under [Inputs/Outputs].

– Deactivate the hardware limit switch for the MultiAxis controller in MOVISUITE® under [Monitoring functions].

Error: 122.66 (7A42hex | 31298dec)

Description: Positive hardware limit switch hit response

 

Response: No response

Cause

Measure

Positive hardware limit switch hit response

– Check the wiring of the hardware limit switch.

– Check the target position.

– Reset the error and exit the hardware limit switch with negative speed.

Error: 122.67 (7A43hex | 31299dec)

Description: Negative hardware limit switch hit response

 

Response: No response

Cause

Measure

Negative hardware limit switch hit response.

– Check the wiring of the negative hardware limit switch.

– Check the target position.

– Reset the error and exit the hardware limit switch with positive speed.

Error: 122.68 (7A44hex | 31300dec)

Description: Object interface not linked

 

Response: No response

Cause

Measure

The library version does not match the code-generated IEC project.

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.69 (7A45hex | 31301dec)

Description: Conversion of object interface failed

 

Response: No response

Cause

Measure

The library version does not match the code-generated IEC project.

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Update the project in MOVISUITE® in the configuration of the controller under [IEC project] by clicking "Update IEC project".

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.70 (7A46hex | 31302dec)

Description: Index variable outside valid range of values

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.71 (7A47hex | 31303dec)

Description: No axis group member with limit switch evaluation connected

 

Response: No response

Cause

Measure

Internal fault

Contact SEW‑EURODRIVE Service.

Error: 122.72 (7A48hex | 31304dec)

Description: Hardware limit switch connections swapped

 

Response: No response

Cause

Measure

The fault can be caused as follows:

– The positive hardware limit switch was hit with a negative direction of rotation or

– The negative hardware limit switch was hit with a positive direction of rotation.

– Check whether the hardware limit switch connections have been swapped.

– Check the effective direction of the drive.

Error: 122.73 (7A49hex | 31305dec)

Description: Both hardware limit switches hit

 

Response: No response

Cause

Measure

Both hardware limit switches hit at the same time.

– Check whether the hardware limit switches have been implemented as NC contacts.

– Check the wiring of the hardware limit switches.

Error: 122.74 (7A4Ahex | 31306dec)

Description: Logical operation not supported

 

Response: No response

Cause

Measure

The logical operation "AND" of the hardware limit switches has been selected, but is no longer supported.

– Switch to an older version of the MultiAxis controller in MOVISUITE®.

– In the event of repeated occurrences, use an older version of the MultiAxis controller and change the logical operation of the hardware limit switches.