Setting up the fieldbus connection

Perform the following steps to allow the MOVI-C® CONTROLLER access to the fieldbus via IEC function blocks. These settings are required for direct fieldbus connection of software modules.

  • A MOVISUITE® project has been created and is open.
  • The MOVISUITE® project includes a MOVI-C® CONTROLLER.
  1. In the function view of MOVISUITE®, click on the node of the MOVI-C® CONTROLLER.
    • The configuration menu of the MOVI‑C® CONTROLLER opens.
  2. In the "MOVIRUN® flexible" configuration menu, open the submenu "Fieldbus".
  3. In the "Fieldbus card" section, select the fieldbus protocol in use.
  4. In the "Fieldbus connection via IEC function blocks" section, set the value of the field "Activate fieldbus connection" to "Yes".
  • The fieldbus connection has been set up successfully.