Process sequence and signal states
INFORMATION
For the behavior of the drive at standstill, observe the information in section "Stop functions" in the "Control functions" configuration menu of the inverter.
INFORMATION
The direction of rotation in this operating mode results from the distance to the target position.
No. | Procedure | PD | Signal states |
---|---|---|---|
[1] General enable |
| PO 1:0 |
|
| PO 1:1 |
| |
| PO 1:13 |
| |
[1] | "Modulo positioning shortest distance" is activated | PO 6 | 404 (decimal) |
Dynamics parameters are applied (also during ongoing movement) | PO 2 PO 3 PO 4 | Setpoint speed Acceleration Deceleration | |
[1] to [5] and from [6] | Start/stop of the axis | PO 1:7 |
|
[2] and [4] | Specification of the setpoint position (a new setpoint position is also adopted during ongoing movement) | PO 7 PO 8 | "Setpoint position" (high word) "Setpoint position" (low word) |
[1] to [2], [3] to [4] and from [7] | If the actual position lies within the configured window width, the feedback "In position" is issued. The drive stops subject to position control. The signal is reset when the operating mode is deselected. | PI 1:7 |
|