Process sequence and signal states

No.

Procedure

PD

Signal states

[1]

Activate touchprobe

When activated, the feedback "Wait for trigger" (TP PI 1:0) is set.

TP
PO 1:0

"0": No trigger event is evaluated

"1": The system waits for a trigger event.

[2]

Trigger

The feedback "Trigger active" (TP PI 1:1) is set, and the trigger counter is increased by 1 (TP PI 2).
The detected relative position is output via TP PI 3 and PI 4.

 

The acquisition of the trigger signal is set in the configuration.

[3]

The touchprobe function is prepared for a new trigger event with a positive edge at "Activate touchprobe" TP PO 1:0.

TP
PO 1:0