Hardware limit switches
The hardware limit switches are connected to the digital inputs configured for this purpose. The cams of the hardware limit switches must cover the travel range up to the stop.
CAUTION
Only use hardware limit switches with NC contacts (low-active).
INFORMATION
Make sure the hardware limit switches are assigned correctly. For clockwise rotation (CW), move the hardware limit switch (LS CW) clockwise and for counterclockwise rotation (CCW), move the hardware limit switch (LS CCW) counterclockwise.
INFORMATION
The hardware limit switches that are used in the software module must not be activated simultaneously in the inverter.
[1] | Drive inverter clockwise rotation (CW) |
[2] | Travel distance |
[3] | Hardware limit switch left (CCW) |
[4] | Hardware limit switch right (CW) |