Process sequence and signal states

INFORMATION

For the behavior of the drive at standstill, observe the information in section "Stop functions" in the "Control functions" configuration menu of the inverter.

No.

Sequence

PD

Signal states

[1]

General enable

  • PO 1:0 = "1"
  • Enable/emergency stop

PO 1:0

  • "1": Enable
  • "0": Deceleration with emergency stop ramp
  • PO 1:1 = "1"
  • Enable/application stop

PO 1:1

  • "1": Enable
  • "0": Deceleration according to application limit

[1]

Selection of operating mode

"Cut length control without material sensor"

PO 6

1400 (decimal)

[1] to [2]

Start of the axis

PO 1:7

PO 18/19

PI 2

  • "1": The drive synchronizes to the master signal in a position-dependent way. The master path is specified by PO 18/19.
  • "0": The drive desynchronizes.

[2]

Drive is synchronous

PI 9:1

  • "1": The drive of the saw is synchronous with the material. Processing can begin.
  • "0": The drive is not synchronous with the material.

[3]

Stop of the axis

PO 1:7

  • "0": The drive desynchronizes with the reference position of the master signal.

[4]

Axis is desynchronized

PI 9:0

  • "0": No master-based operating mode active.