Inspection and maintenance intervals

The following table shows the inspection intervals:

Time interval

What to do?

Who is permitted to perform the work?

When the electronics cover is opened after an operating period of ≥ 6 months.

When the electronics cover is opened after an operating period of ≥ 6 months, the gasket between the connection box and the electronics cover must always be replaced.

The 6-month period can be shortened by harsh ambient/operating conditions, e.g. cleaning with aggressive chemicals or frequent temperature variations.

Specialists at customer site

Each time the electronics cover is opened

Visual inspection of the gasket between connection box and electronics cover: Replace the gasket if it is damaged or separating from the connection box.

Specialists at customer site

Varying (depending on external factors)

Touch up or renew the surface/anti-corrosion coating

Specialists at customer site