Inspection and maintenance intervals
The following table shows the inspection intervals:
Time interval | What to do? | Who is permitted to perform the work? |
---|---|---|
When the electronics cover is opened after an operating period of ≥ 6 months. | When the electronics cover is opened after an operating period of ≥ 6 months, the gasket between the connection box and the electronics cover must always be replaced. The 6-month period can be shortened by harsh ambient/operating conditions, e.g. cleaning with aggressive chemicals or frequent temperature variations. | Specialists at customer site |
Each time the electronics cover is opened | Visual inspection of the gasket between connection box and electronics cover: Replace the gasket if it is damaged or separating from the connection box. | Specialists at customer site |