Potentiometer f2
NOTICE
Loss of the ensured degree of protection if the screw plug of the potentiometer is not installed or not installed correctly.
Damage to the device.
- After setting the setpoint, make sure the screw plug of the potentiometer has a seal and screw it in.
Use the potentiometer f2 to adjust speed setpoint f2.
- When the device is set to Easy mode, the predefined setpoint is always active at the potentiometer f2.
- The potentiometer f2 can be deactivated in Expert mode. In this case, the parameterizable replacement value is activated as speed setpoint f2.
The following figure shows how to scale the speed setpoint f2 using potentiometer f2:
1) | Depending on the selected direction of rotation, the parameter Application limit positive or the parameter Application limit negative are used to scale the speed setpoint f2. You can find the application limits in the MOVISUITE® parameter tree at: Functions > Monitoring functions > Limit values > Application limit. |