Basic settings
Parameter name | Description |
|---|---|
General | |
Activate simulation |
|
Index: 50000.2 | |
IEC name: Inverter.In.xSimulation | |
Functions used | |
Position controller Information: The Configuration menu becomes visible when activated. | Activate or deactivate the functions for central position control and encoder evaluation |
Index: 50000.102 | |
IEC name: _fbController._stConfig.stOptionalModes.xAddonPositionController | |
Energy coupling Information: The Configuration menu becomes visible when activated. | Activate or deactivate the function to couple the software module with a power supply module for exchanging energy data. The actual function is implemented via a software module on the power supply module when it is activated. |
Index: 50100.240 | |
IEC name: - | |
Variable jerk | Activate or deactivate the function for variable presetting of the jerk. INFORMATION: When using the additional function, refer to the more detailed information in chapter Variable jerk. |
Index: 50040.100 | |
IEC name: - | |
Touchprobe 1 Information: Activating this function is a prerequisite for the "Automatic – cut mark control" operating mode. The Configuration menu becomes visible when activated. | Function for reading the detected position and the trigger counter in the event of a trigger event. |
Index: 50000.20 | |
IEC name: - | |