Status (OUT)

The status of the operating mode is output via the following output variables.

Variable name

Description

xDischargeActive

Data type – BOOL

  • TRUE – Discharging of the DC link is active. The braking resistor is controlled via the internal brake chopper.
  • FALSE – Discharging of the DC link is not active.

xDischargeComplete

Data type – BOOL

  • TRUE – The target voltage for discharging the DC link has been reached.
  • FALSE – The target voltage for discharging the DC link has not been reached.

xHighPowerError

Data type – BOOL

  • TRUE – The braking resistor is overridden, meaning the current discharging capacity is at least 10% higher than the specified maximum capacity.
  • FALSE – The discharging capacity meets specifications.

rActualDischargePower

Data type – REAL

Current discharging capacity [W]

rActualDCVoltage

Data type – REAL

Current voltage of the DC link [V]

uiResidualDischargeTime

Data type: UINT

Estimated remaining time until the target voltage is reached [s]