Cycle times
The cycle times listed as follows will result depending on which hardware and software components are used. These cycle times must be set on the MOVI‑C® CONTROLLER and/or on the inverters. For information on how to set the cycle time, refer to chapter Setting the cycle time.
The following specifications apply with regard to the software used:
- When using the following components, set the cycle time on the MOVI‑C® CONTROLLER and on the inverters to ≤ 2 ms:
- MOVIKIT® MultiMotion add-on PositionController
- MOVIKIT® MultiMotion add-on CombinedEncoderEvaluation
- When using the MOVIKIT® Motion add‑on AntiSway, set the cycle time on the MOVI-C® CONTROLLER and on the inverters to < 2 ms.
If you want to use other cycle times, contact SEW‑EURODRIVE Service.