Fault codes

The software module can set the following fault/error codes: All codes trigger the error response "Error message + emergency stop (10)".

Hex

Dec

Description

16#9000

36864

The process data channel could not be activated during the initialization of the function block. The device might not be connected to the SBUSPLUS or is not actively supplied with 24 V.

16#9001

36865

The initialization of internal filters and blocks could not be completed.

16#9002

36866

Certain parameters could not be read from the device during initialization. The SBUSPLUS might not be able to access the device.

16#9003

36867

The initialization of the function block failed during the initial phase. It is possible that the license manager could not be initialized.

16#9004

36868

The device signals a fault. The exact fault code of the device can be found in the "Inverter" structure.

16#9005

36869

The device signals an active FCB (FunctionControlBlock) that is unknown to the control system. The library version and the device firmware version might not match.

16#9006

36870

The connected device is not compatible with the software module.

16#900A

36874

The device signals a warning. You can find the warning text in the "Inverter" structure.

16#9007

36871

Communication error warning:

Process data could not be read from the device.