IN

Variable name

Description

xActivate

Data type – BOOL

  • TRUE – Activate
  • FALSE – Stop
    • If xActivate is set to "FALSE" and lrStopDeceleration" is ≤ 0, the operating mode stops at the last setpoint position, and speed and acceleration go to zero.
    • If xActivate is set to "FALSE" and lrStopDeceleration" is > 0, profile generation stops with the deceleration lrStopDeceleration and the set jerk lrStopJerk.

xStart

Data type – BOOL

  • TRUE – Start function
  • FALSE – Stop function

lrUserProgram
SourceSetpoint

Data type: LREAL – Floating-point number

A signal generated by the user in the IEC program that is to be used as a Touchprobe source ("User program" data source).

The signal is cyclically transmitted to the inverter with the process data where it is used as the Touchprobe source.