Process sequence and signal states

Procedure

PD

Signal states

General enable

  • PO 1:0 = "1"

PO 1:0

  • "1": Enable
  • "0": Active brake test is aborted.
  • PO 1:1 = "1"

PO 1:1

  • "1": Enable
  • "0": Active brake test is aborted.
  • PO 1:13 = "0"

PO 1:13

  • "1": Output stage inhibited (active brake test is aborted).
  • "0": Output stage enabled

Operating mode

Activation of "brake test" application mode

PO 6

  • 700 (decimal)

Start/stop

Start/stop brake test

PO 1:7

  • "1": The brake test is being performed.
  • Prerequisite: Drive enabled and not in fault state.
  • "0": Active brake test is aborted.

Status and test results of the brake test are transferred for brake 1 and brake 2 via a process data word of the process input data of the additional functions.