Adjusting the drive axis

  1. Start up the drive axis used as described in the associated documentation.
  2. Configure the units for scaling the drive axis as follows:
    • Travel distance: rev
    • Speed: min-1
    • Acceleration: rev/(min*s)
  1. In the "Limit Values" submenu of the "Monitoring Function" configuration menu, configure the cycle limitation as follows (INFORMATION: Only required if the actual position is transferred in the modulo unit, e.g. when using MOVIKIT® MultiMotion Auxiliary Positioning and if plausibility monitoring of the diameter should be used.):
    • Modulo minimum: 0
    • Modulo maximum: 1