Brake test measured values

According to the selection PO n+0 of the brake test measured values and the selection mirrored in process input data word PI n+1, the measured values of the selected brake are displayed in PI n+1 to PI n+4. This data is available regardless of the operating mode and can therefore be called up if the inverter drive function "FCB 21 Brake test" is not active.

Word

Bit

Function/additional information

PI n+0

Member (high byte)/brake (low byte)

0-15

Member (high byte) / brake (low byte) of the displayed brake test measured values

PI n+1

Load torque determined/specified

0-15

 

PI n+2

Measured motor torque [0.1 Nm]

0-15

 

PI n+3

Total torque [0.1 Nm]

0-15

 

PI n+4

Measured movement

0-15

In user units