Cycle times
Setting the cycle time is only relevant when using MOVIRUN® flexible.
The cycle times listed as follows will result depending on which hardware and software components are used. These cycle times must be set on the MOVI‑C® CONTROLLER and/or on the inverters. For information on how to set the cycle time, refer to chapter Setting the cycle time.
MOVIKIT® StackerCrane effiDRIVE with… | MOVI-C® CONTROLLER UHX ... | |||||
|---|---|---|---|---|---|---|
15 A | 25 A | 45A | 65A-R02 | 86 A | ||
MOVIKIT® StackerCrane MultiMotion | 4 ms | 4 ms | 1 ms | 1 ms | 1 ms | |
+ | MOVIKIT® PowerMode | 4 ms | 4 ms | 1 ms | 1 ms | – |
MOVIKIT® StackerCrane MultiAxisController | – | – | 4 ms | 1 ms | 1 ms | |
+ | MOVIKIT® Motion addon AntiSway | – | – | 4 ms | 4 ms | 1 ms |
+ | MOVIKIT® MultiAxisController addon Cascading | – | – | 4 ms | 4 ms | 1 ms |
+ | MOVIKIT® PowerMode | 4 ms | 4 ms | 4 ms | 4 ms | – |
If you want to use other cycle times, contact SEW‑EURODRIVE Service.