Power connection with line contactor size 8
The following figure shows an example of the wiring of the power connections with a line contactor, line choke, line filter and output choke.
All duplicate connections are connected internally. The wiring can therefore be connected to either one of the terminals or to both terminals.

[1] | Fuses |
[2] | Line contactor |
[3] | Line choke (optional) |
[4] | Line filter (optional) |
[5] | Braking resistor (optional) |
[6] | Output choke (optional) |
[7] | Motor |