Short-circuiting modules
Short-circuit all modules of the storage bundle, even if not all modules are to be replaced. The short-circuited poles ensure that the voltage positions are the same when a new energy module is installed and that there are no asymmetries.
Proceed as follows:
- You have set the system to a safe state according to the specifications in chapter Discharging energy storage units before service work.
- Disconnect the electrical connections on module 1.
- Short-circuit module 1 using the insulated single-core cable mentioned above.
- Disconnect the electrical connection on the negative pole of module 2.
- Short-circuit module 2 using the original connection lead between module 1 and 2.
- Perform steps 3 and 4 for all remaining modules of the storage bundle.