Virtual inputs via process output data
The parameter "Read reference cam and HW limit switch via PO5" (8463.3, bit 19/20) can be set in the MOVIKIT Positioning Drive / inputs/outputs configuration menu.
Parameter designation | Value |
|---|---|
Read reference cams and HW limit switches via PO 5 | Activation of reading virtual inputs via process output data via PO 5.
|
Index: 8463.3 Bit 19/20 |
If the setting of the parameter "Read reference cams and HW limit switches via PO 5" (8483.3, bit 19/20) is defined as "virtual inputs via PO 5 via PO 5 bit 0 – 3", the digital outputs can no longer be controlled via PO 5. If necessary, the digital outputs must be configured to another function. If both the function of the virtual inputs is to be used and the digital outputs are to be controlled via PO 5, the setting "... via PO 5 bit 8 – 15" must be specified.