Process sequence and signal states

No.

Sequence

PD

Signal states

[1]

Activate Touchprobe

When activated, the feedback "Trigger tripped" (TP PI 1:0) is set.

TP
PO X:0

"0": No trigger event is evaluated

“1”: The system waits for a trigger event.

[2]

Trigger

The feedback "Trigger active" (TP PI X:1) is set, and the value int "Touchprobe 1 – trigger – counter" is increased by 1 (TP PI X+1).

The detected value is output via TP PI X+2 and PI X+3.

 

[3]

The Touchprobe function is prepared for a new trigger event with a positive edge at "Activate Touchprobe 1" (TP PO X:0).

TP
PO X:0