Drive and gear unit selection data

Determining application data

First, you require the data of the machine to be driven (mass, rotational speed, setting range, etc.) to select the correct drive. This data helps determine the required power, torque and speed. Refer to the documentation "Drive engineering – practical implementation – project planning for controlled and non-controlled drives" or the "SEW-Workbench" project planning software.

Selecting the correct drive

Calculate the power, rotational speed, torque, and overhung load of the drive. Observe all mechanical requirements. The suitable drive can then be determined.

Motors with adapter

As the motor dimensions are not standardized, the following motor data must be known to select the appropriate adapter:

  • Shaft diameter and length
  • Flange dimensions (edge length, diameter, centering shoulder, and hole circle)
  • Maximum torque

Contact SEW‑EURODRIVE if you have any questions on selection and project planning.

Application data required for project planning:

Formula symbol

 

Unit

Description

FA_a

N

Axial force (tension and pressure) on the output shaft

fline

Hz

Line frequency

FR_a

N

Overhung load acting on the output shaft

h

m above sea level

Installation altitude

JL

10-4 kgm2

Mass moment of inertia to be driven

Ma at namax

Nm

Output torque at maximum output speed

Ma at namin

Nm

Output torque at minimum output speed

MB

Nm

Braking torque

namax

min-1

Maximum output speed

namin

min-1

Minimum output speed

Pa at namax

kW

Output power at maximum output speed

Pa at namin

kW

Output power at minimum output speed

M1 – M6

R, F, K, S, W

Required gear unit type and mounting position

S.., ..% cdf

Duty type and cyclic duration factor cdf – the exact load cycle can be entered instead

Tamb

°C

Ambient temperature

VN

V

Nominal brake voltage

VMot

V

Motor voltage

Z

h-1

Switching frequency – alternatively, the exact load cycle can be specified

For inverter operation: required control mode and setting range.