Errort 12 Brake

Error: 12.13 (0C0Dhex | 3085dec)

Description: Faulty voltage

 

Response: Output stage inhibit

Cause

Measure

The voltage of the brake output is not compatible with the nominal voltage of the brake that was started up.

– Check brake startup.

or

– Use device with appropriate brake voltage.

or

– Use drive with appropriate brake.

Error: 12.20 (0C14hex | 3092dec)

Description: Digital motor integration – critical error

 

Response: Output stage inhibit with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has detected a critical error.

Observe the error message of the subslave. Identify the exact cause of this error message and take the appropriate measures to eliminate the error.

Error: 12.21 (0C15hex | 3093dec)

Description: Digital motor integration – error

 

Response: Emergency stop + output stage inhibit with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has detected an error.

Observe the error message of the subslave. Identify the exact cause of this error message and take the appropriate measures to eliminate the error.

Error: 12.22 (0C16hex | 3094dec)

Description: Digital motor integration – warning

 

Response: Warning with self-reset

Cause

Measure

The intelligent brake rectifier of digital motor integration has signaled a warning.

Observe the warning of the subslave. Identify the exact cause of this warning and take the appropriate measures for elimination.

Error: 12.23 (0C17hex | 3095dec)

Description: Digital motor integration – timeout

 

Response: Output stage inhibit

Cause

Measure

Communication with the intelligent brake rectifier is disrupted.

Check the connection.

Error: 12.24 (0C18hex | 3096dec)

Description: Digital motor integration – initialization error

 

Response: Output stage inhibit

Cause

Measure

Initialization of the intelligent brake rectifier has failed.

– Acknowledge the error.