Error 149 MOVIKIT® – Controller firmware
Error: 149.00 (9500hex | 38144dec) Description: Invalid speed of at least one cam | ||
|---|---|---|
|
| |
Cause | Measure | |
The speed of at least one cam is less than or equal to 0. | Select a value within the valid range of values. | |
Error: 149.01 (9501hex | 38145dec) Description: Invalid lower limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
The lower limit speed is greater than the maximum speed or minimum speed or less than 0. | Select limit speed (VLimit) in the valid range of values. | |
Error: 149.02 (9502hex | 38146dec) Description: Invalid arrangement of speed cams | ||
|---|---|---|
|
| |
Cause | Measure | |
The order of the lower and upper cams is incorrect. | Specify cams in the correct sequence. | |
Error: 149.03 (9503hex | 38147dec) Description: Sampling cycle invalid | ||
|---|---|---|
|
| |
Cause | Measure | |
The sampling cycle is less than or equal to 0. | Select a value within the valid range of values. | |
Error: 149.04 (9504hex | 38148dec) Description: Error in basic profile generator | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred while calculating the travel profile when approaching the speed cams. For detailed information, refer to the debug variables. | Contact SEW‑EURODRIVE Service. | |
Error: 149.05 (9505hex | 38149dec) Description: Reference specification invalid | ||
|---|---|---|
|
| |
Cause | Measure | |
Some function blocks require a reference to a variable structure (e.g. the speed cams). The variable structure is invalid here. | Select the correct variable structure. | |
Error: 149.06 (9506hex | 38150dec) Description: Invalid target platform | ||
|---|---|---|
|
| |
Cause | Measure | |
The function block can only be operated on an SEW controller. | Use correct control. | |
Error: 149.07 (9507hex | 38151dec) Description: Error at speed cam profile generator of the x axis | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred in the x-axis while calculating the travel profile for approaching the speed cams. For detailed information, refer to the debug variables. | Contact SEW‑EURODRIVE Service. | |
Error: 149.08 (9508hex | 38152dec) Description: Error at speed cam profile generator of the y axis | ||
|---|---|---|
|
| |
Cause | Measure | |
A calculation error occurred in the y-axis while calculating the travel profile for approaching the speed cams. For detailed information, refer to the debug variables. | Contact SEW‑EURODRIVE Service. | |
Error: 149.160 (95A0hex | 38304dec) Description: Faulty calculation of the position distance between start speed and end speed | ||
|---|---|---|
|
| |
Cause | Measure | |
A correct approach of the speed cams requires the point in time for braking. Error while calculating the time. | Contact SEW‑EURODRIVE Service. | |
Error: 149.161 (95A1hex | 38305dec) Description: Missing feed enable | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization cannot be performed due to missing feed enable. | Set the start signal. | |
Error: 149.164 (95A4hex | 38308dec) Description: Error at profile generator of the x-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization is not performed because an error has occurred at the profile generator of the x-axis. | Contact SEW‑EURODRIVE Service. | |
Error: 149.165 (95A5hex | 38309dec) Description: Error at profile generator of y-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
Optimization is not performed because an error has occurred at the profile generator of the y-axis. | Contact SEW‑EURODRIVE Service. | |
Error: 149.170 (95AAhex | 38314dec) Description: Speed of the y-axis < limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the speed of the y-axis is lower than the limit speed. | Increase limit speed (VLimit). | |
Error: 149.171 (95ABhex | 38315dec) Description: Invalid time base for y-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the time base for the y-axis is less than or equal to 0. | Select the correct time delay. | |
Error: 149.172 (95AChex | 38316dec) Description: Speed of the x-axis < limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
There is no synchronous operation as the speed of the x-axis is lower than the limit speed. | Increase limit speed (VLimit). | |
Error: 149.173 (95ADhex | 38317dec) Description: Invalid time base for x-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
No synchronous operation takes place because the time base for the x-axis is less than or equal to 0. | Specify a correct time delay. | |
Error: 149.174 (95AEhex | 38318dec) Description: Speed of the y-axis < limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
The x-axis determines the total time of positioning and the y-axis is in lowering mode. There is no optimization as the speed of the y-axis is lower than the limit speed. | Increase limit speed (VLimit). | |
Error: 149.175 (95AFhex | 38319dec) Description: Invalid stop time | ||
|---|---|---|
|
| |
Cause | Measure | |
The x-axis determines the total time of positioning and the y-axis is in lowering mode. No optimization takes place because the stop time is 0. | Contact SEW‑EURODRIVE Service. | |
Error: 149.176 (95B0hex | 38320dec) Description: Invalid time base for y-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
The x-axis determines the total time of positioning and the y-axis is in lowering mode. There is no optimization as the time base for the y-axis is less than or equal to 0. | Select the correct time delay. | |
Error: 149.177 (95B1hex | 38321dec) Description: Speed of the x-axis < limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
The y-axis determines the total time of positioning and is in lifting mode. There is no optimization as the speed of the x-axis is lower than the limit speed. | Increase limit speed (VLimit). | |
Error: 149.178 (95B2hex | 38322dec) Description: Invalid time base for x-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
The y-axis determines the total time of positioning and is in lifting mode. There is no optimization as the time base for the x-axis is less than or equal to 0. | Select the correct time delay. | |
Error: 149.179 (95B3hex | 38323dec) Description: Speed of the x-axis < limit speed | ||
|---|---|---|
|
| |
Cause | Measure | |
The y-axis determines the total time of positioning and is in lowering mode. There is no optimization as the speed of the x-axis is lower than the limit speed. | Increase limit speed (VLimit). | |
Error: 149.180 (95B4hex | 38324dec) Description: Invalid stop time | ||
|---|---|---|
|
| |
Cause | Measure | |
The y-axis determines the total time of positioning and is in lowering mode. No optimization takes place because the stop time is 0. | Contact SEW‑EURODRIVE Service. | |
Error: 149.181 (95B5hex | 38325dec) Description: Invalid time base for x-axis | ||
|---|---|---|
|
| |
Cause | Measure | |
The y-axis determines the total time of positioning and is in lowering mode. There is no optimization as the time base for the x-axis is less than or equal to 0. | Select the correct time delay. | |
Error: 149.240 (95F0hex | 38384dec) Description: Warning: Value transferred to the inverter too large | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW-EURODRIVE Service. | |
Error: 149.241 (95F1hex | 38385dec) Description: Warning: Value transferred to the inverter too small | ||
|---|---|---|
|
| |
Cause | Measure | |
Internal error | Contact SEW‑EURODRIVE Service. | |
Error: 149.242 (95F2hex | 38386dec) Description: Inverter warning | ||
|---|---|---|
|
| |
Cause | Measure | |
An inverter warning is present. | Observe the description in MOVISUITE® or the inverter manual. | |