Error 149 MOVIKIT® – Controller firmware

Error: 149.00 (9500hex | 38144dec)

Description: Invalid speed of at least one cam

 

 

Cause

Measure

The speed of at least one cam is less than or equal to 0.

Select a value within the valid range of values.

Error: 149.01 (9501hex | 38145dec)

Description: Invalid lower limit speed

 

 

Cause

Measure

The lower limit speed is greater than the maximum speed or minimum speed or less than 0.

Select limit speed (VLimit) in the valid range of values.

Error: 149.02 (9502hex | 38146dec)

Description: Invalid arrangement of speed cams

 

 

Cause

Measure

The order of the lower and upper cams is incorrect.

Specify cams in the correct sequence.

Error: 149.03 (9503hex | 38147dec)

Description: Sampling cycle invalid

 

 

Cause

Measure

The sampling cycle is less than or equal to 0.

Select a value within the valid range of values.

Error: 149.04 (9504hex | 38148dec)

Description: Error in basic profile generator

 

 

Cause

Measure

A calculation error occurred while calculating the travel profile when approaching the speed cams. For detailed information, refer to the debug variables.

Contact SEW‑EURODRIVE Service.

Error: 149.05 (9505hex | 38149dec)

Description: Reference specification invalid

 

 

Cause

Measure

Some function blocks require a reference to a variable structure (e.g. the speed cams). The variable structure is invalid here.

Select the correct variable structure.

Error: 149.06 (9506hex | 38150dec)

Description: Invalid target platform

 

 

Cause

Measure

The function block can only be operated on an SEW controller.

Use correct control.

Error: 149.07 (9507hex | 38151dec)

Description: Error at speed cam profile generator of the x axis

 

 

Cause

Measure

A calculation error occurred in the x-axis while calculating the travel profile for approaching the speed cams. For detailed information, refer to the debug variables.

Contact SEW‑EURODRIVE Service.

Error: 149.08 (9508hex | 38152dec)

Description: Error at speed cam profile generator of the y axis

 

 

Cause

Measure

A calculation error occurred in the y-axis while calculating the travel profile for approaching the speed cams. For detailed information, refer to the debug variables.

Contact SEW‑EURODRIVE Service.

Error: 149.160 (95A0hex | 38304dec)

Description: Faulty calculation of the position distance between start speed and end speed

 

 

Cause

Measure

A correct approach of the speed cams requires the point in time for braking. Error while calculating the time.

Contact SEW‑EURODRIVE Service.

Error: 149.161 (95A1hex | 38305dec)

Description: Missing feed enable

 

 

Cause

Measure

Optimization cannot be performed due to missing feed enable.

Set the start signal.

Error: 149.164 (95A4hex | 38308dec)

Description: Error at profile generator of the x-axis

 

 

Cause

Measure

Optimization is not performed because an error has occurred at the profile generator of the x-axis.

Contact SEW‑EURODRIVE Service.

Error: 149.165 (95A5hex | 38309dec)

Description: Error at profile generator of y-axis

 

 

Cause

Measure

Optimization is not performed because an error has occurred at the profile generator of the y-axis.

Contact SEW‑EURODRIVE Service.

Error: 149.170 (95AAhex | 38314dec)

Description: Speed of the y-axis < limit speed

 

 

Cause

Measure

There is no synchronous operation as the speed of the y-axis is lower than the limit speed.

Increase limit speed (VLimit).

Error: 149.171 (95ABhex | 38315dec)

Description: Invalid time base for y-axis

 

 

Cause

Measure

There is no synchronous operation as the time base for the y-axis is less than or equal to 0.

Select the correct time delay.

Error: 149.172 (95AChex | 38316dec)

Description: Speed of the x-axis < limit speed

 

 

Cause

Measure

There is no synchronous operation as the speed of the x-axis is lower than the limit speed.

Increase limit speed (VLimit).

Error: 149.173 (95ADhex | 38317dec)

Description: Invalid time base for x-axis

 

 

Cause

Measure

No synchronous operation takes place because the time base for the x-axis is less than or equal to 0.

Specify a correct time delay.

Error: 149.174 (95AEhex | 38318dec)

Description: Speed of the y-axis < limit speed

 

 

Cause

Measure

The x-axis determines the total time of positioning and the y-axis is in lowering mode. There is no optimization as the speed of the y-axis is lower than the limit speed.

Increase limit speed (VLimit).

Error: 149.175 (95AFhex | 38319dec)

Description: Invalid stop time

 

 

Cause

Measure

The x-axis determines the total time of positioning and the y-axis is in lowering mode. No optimization takes place because the stop time is 0.

Contact SEW‑EURODRIVE Service.

Error: 149.176 (95B0hex | 38320dec)

Description: Invalid time base for y-axis

 

 

Cause

Measure

The x-axis determines the total time of positioning and the y-axis is in lowering mode. There is no optimization as the time base for the y-axis is less than or equal to 0.

Select the correct time delay.

Error: 149.177 (95B1hex | 38321dec)

Description: Speed of the x-axis < limit speed

 

 

Cause

Measure

The y-axis determines the total time of positioning and is in lifting mode. There is no optimization as the speed of the x-axis is lower than the limit speed.

Increase limit speed (VLimit).

Error: 149.178 (95B2hex | 38322dec)

Description: Invalid time base for x-axis

 

 

Cause

Measure

The y-axis determines the total time of positioning and is in lifting mode. There is no optimization as the time base for the x-axis is less than or equal to 0.

Select the correct time delay.

Error: 149.179 (95B3hex | 38323dec)

Description: Speed of the x-axis < limit speed

 

 

Cause

Measure

The y-axis determines the total time of positioning and is in lowering mode. There is no optimization as the speed of the x-axis is lower than the limit speed.

Increase limit speed (VLimit).

Error: 149.180 (95B4hex | 38324dec)

Description: Invalid stop time

 

 

Cause

Measure

The y-axis determines the total time of positioning and is in lowering mode. No optimization takes place because the stop time is 0.

Contact SEW‑EURODRIVE Service.

Error: 149.181 (95B5hex | 38325dec)

Description: Invalid time base for x-axis

 

 

Cause

Measure

The y-axis determines the total time of positioning and is in lowering mode. There is no optimization as the time base for the x-axis is less than or equal to 0.

Select the correct time delay.

Error: 149.240 (95F0hex | 38384dec)

Description: Warning: Value transferred to the inverter too large

 

 

Cause

Measure

Internal error

Contact SEW-EURODRIVE Service.

Error: 149.241 (95F1hex | 38385dec)

Description: Warning: Value transferred to the inverter too small

 

 

Cause

Measure

Internal error

Contact SEW‑EURODRIVE Service.

Error: 149.242 (95F2hex | 38386dec)

Description: Inverter warning

 

 

Cause

Measure

An inverter warning is present.