Extended gearing functions

 

Note that the configuration menu is only displayed if the parameter "Synchronous operation function" is set to "Extended" in the "Basic settings" configuration menu under "Additional functions".

Parameter designation

Description

In adjust window

Half window width [1]

Configuration of the slave axis. If the difference between the actual master and slave position is ≤ this value, the "InAdjustWindow" signal is set.

(in user units)

Default value: 0

Index: 50041.13

IEC name: –

Adjust error

Half window width [2]

Configuration of the slave axis. If the difference between the actual master and slave position is ≤ this value, an adjustment process is permitted. If the difference is greater, no adjustment is permitted and an error message is displayed.

If the value 0 is set, no check is available and the adjustment process is always possible.

(in user units)

Default value: 0

Index: 50041.14

IEC name: –