Reference travel

 

Note that this configuration menu is only displayed when virtual axes are used. The reference travel of real axes is configured in the configuration menu "Drive functions" > "FCB12 reference travel".

Parameter designation

Description

Reference travel

Reference travel type

Referencing without reference travel

Index: 50007.1

IEC name: ProfileGeneration.Homing.Config.eReferenceTravelType

Reference offset

Deviation of the cam from the machine zero

(in user units)

Index: 50007.2

IEC name: ProfileGeneration.Homing.Config.lrReferenceOffset

Advanced settings

Save referencing in a power failure-safe manner

  • Yes
    Referencing is saved in a power failure-safe manner. A referenced axis reports the signal even after the MOVI-C® CONTROLLER is switched on again.
  • No
    Do not save referencing in a power failure-safe manner.

Index: 50007.12

IEC name: –