Cycle times

The cycle times listed as follows will result depending on which hardware and software components are used. These cycle times must be set on the MOVI‑C® CONTROLLER and/or on the inverters. For information on how to set the cycle time, refer to chapter Setting the cycle time.

MOVIKIT® Gearing with ...

Cycle time

MOVIKIT® MultiMotion addon PositionController

≤ 2 ms

MOVIKIT® MultiMotion addon CombinedEncoderEvaluation

≤ 2 ms

MOVIKIT® Motion addon AntiSway

< 2 ms

If you want to use other cycle times, contact SEW‑EURODRIVE Service.