Cycle times
The cycle times listed as follows will result depending on which hardware and software components are used. These cycle times must be set on the MOVI‑C® CONTROLLER and/or on the inverters. For information on how to set the cycle time, refer to chapter Setting the cycle time.
MOVIKIT® Gearing with ... | Cycle time |
|---|---|
MOVIKIT® MultiMotion addon PositionController | ≤ 2 ms |
MOVIKIT® MultiMotion addon CombinedEncoderEvaluation | ≤ 2 ms |
MOVIKIT® Motion addon AntiSway | < 2 ms |
If you want to use other cycle times, contact SEW‑EURODRIVE Service.