Touchprobe 1

 

Note that this configuration menu is only displayed if the function is activated in the "Basic settings" configuration menu under "Additional functions".

Parameter designation

Description

Status

Wait for trigger

Activated, if waiting for a trigger event.

Index: 8352.2, Bit0

IEC name: Parameter.TouchProbe1.Status

Trigger activated

Activated when a trigger event has occurred.

Index: 8352.2, Bit1

IEC name: Parameter.TouchProbe1.Status

Detected value

Position at the time of the trigger event

Index: 8352.3

IEC name: Parameter.TouchProbe1.DetectedVal

Trigger

Source

Source for activating the trigger for recording a signal

Index: 8352.10

IEC name: –

Event

Selection of the edge type for which the action is triggered:

  • Rising edge
  • Falling edge
  • Rising and falling edge

Index: 8352.11

IEC name: –

Sensor dead time rising edge

INFORMATION: Visible when a "Rising edge" event occurs.

Dead time of the sensor used for the rising edge at the trigger input. This time will be included in the calculation of the touchprobe result value.

(in ms)

Default value: 0.000

Index: 8352.12

IEC name: Parameter.TouchProbe1.TriggerSensorDeadTimeRisingEdge

Sensor dead time falling edge

INFORMATION: Visible when a "Falling edge" event occurs.

Dead time of the sensor used for the falling edge at the trigger input. This time will be included in the calculation of the touchprobe result value.

(in ms)

Default value: 0.000

Index: 8352.13

IEC name: Parameter.TouchProbe1.TriggerSensorDeadTimeFallingEdge

Counter

Counter of trigger events. This value is incremented by the value 1 with each trigger event.

Index: 8352.14

IEC name: Parameter.TouchProbe1.TriggerCounter

Data source

Data source

Selection of the data source for recording.

If you have selected a PO data word as the data source, observe the settings in the inverter configuration menu "Functions > Touchprobe 1".

INFORMATION: If you have configured modulo limits, set "Actual position in user units – modulo".

Default value: No function

Index: 8352.30

IEC name: –